Coo,ro,.and,o
// I 1. MovecontrolhandleFORWARDor DOWNto split
Z_I 1_1 , wood.
2. Releasethe controlhandleto stopthewedgemove-
ment.
3. MovecontrolhandleBACKor UPto returnthe wedge.
Neverremove partially
split wood from the
wedge with your
hands. Fingers may be-
come trapped between
split wood.
Log Dislodger
Thelog dislodgerisdesignedto removeany partially
splitwoodfromthewedge.Thismayoccurwhilesplitting
largediameterwoodorfreshlycutwood.
_ ARNING:Neverremove partiallysplit
wood from the wedge with your hands.
Fingersmaybecome trapped between
split wood.
Figure 4=3
Before Each Use
1. Removethedipstickand checkhydraulicfluidlevel.
Refillif necessary.ApprovedfluidsincludeDexron®
III / Mercon®IIIautomatictransmissionfluid,a
10WeightAWhydraulicoilor Pro-MixTM AW-32
HydraulicOil.
2. Check engineoil level.Refillifnecessary.
3. Fill upgasolineif necessary.
4. Lubricatethe beamareawheresplittingwedgewill
slidewithengineoil. Donot usegreaseto lubricate.
Makesureto lubricateboththe frontandthe backof
the beamface.
5. Attachsparkplugwireto thesparkplug.
Using the Log Splitter
1. Placethe logsplitteronlevel,dry ground.
2. Placethe beamineitherthe horizontalorvertical
positionandlockinplacewiththeappropriate
lockingrod.
3. Blockthe frontandbackof bothwheels.
4. Placethe logagainstthe endplateandonlysplit
woodinthedirectionof the grain.
5. Tostabilizethe log,placeyour handonly on sidesof
log.Neverplacehandon the end betweenthe log
and the splittingwedge.
6. Onlyoneadult shouldstabilizethe logandoperate
the controlhandle,so the operatorhasfull control
overthe logandthe splittingwedge.
1. Toremovepartiallysplitwoodfromwedge,move
controlhandleto REVERSEpositionuntilwedgeis
fullyretractedto allowsplitwoodportionto contactthe
logdislodger.
2. Onceremovedfromwedgewith logdislodger,split
woodfromoppositeendor inanotherlocation.
Vertical Position
1. Pullthe horizontalbeamlockout to releasethe beam
andpivotthe beamto the verticalposition.
2. Tolockthe beamin theverticalposition,pullout
onthe verticalbeamlockandrotateit to securethe
beam.SeeFigure4-1.
3. Standinfrontof the unit to operatethe controlhandle
andto stabilizethe log. SeeFigure4-3.
Horizontal Position
1. Pulltheverticalbeamlockout and rotateit down.See
Figure4-1.Pivotbeamto the horizontalposition.The
beamwill lockautomaticallyinhorizontalposition.
2. Standbehindthe reservoirtankto operatecontrol
handleandto stabilizethe log.
Operating Tips
Always:
1. Usecleanfluidandcheckfluid levelregularly.
2. Useanapprovedhydraulicfluid.Approvedfluids
includeDexron®III/Mercon®IIIautomatictransmis-
sionfluid,a 10WeightAWhydraulicoil or Pro-MixTM
AW-32HydraulicOil.
3. Useafilter (cleanor replaceregularly).
4. Usea breathercapon fluidreservoir.
5. Makesure pumpis mountedandalignedproperly.
10