Przeglądanie stron 5
404
Parker Hannifin
Hydraulic Filter Division Europe
FDHB500UK.
icountLaserCM20
PortableParticleCounter
Why On-Site Fluid Contamination Monitoring?
Data Download Management
Dedicatedsoftware,providesthelinkbetweenan
icountLaserCM20 and the H
2Oil - Water in Oil monitor
and your computer management system.
Certification of fluid cleanliness levels.
Earlywarninginstrumenttohelpprevent
catastrophic failure in critical systems.
Immediateresultswithlaboratoryaccuracy.
To comply with customer cleanliness
requirementsandspecifications.
Newequipmentwarrantycompliance.
New oil cleanliness testing.
icountLaserCM Test
ONLINETEST
TESTNUMBER022
DMY
Date 04-03-10
Time 15-52
ISO: 20/15/09
Count/100ml
>4µ(c) 820721
>6µ(c) 31564
>14µ(c) 314
>21µ(c)  64
>38µ(c)  14
>70µ(c)  0
NOTES
ISO4406-1999 CorrelationtoNAS1638
16-columnprinterforhardcopydata.Afeatureofthe
icountLaserCMistheon-boardprintoutdatagraphingoption
developed to support predictive maintenance procedures.
icountLaserCM Test
ONLINETEST
TESTNUMBER022
DMY
Date 04-03-10
Time 15-52
NASCLASS: 7
Count/100ml
4/6µ(c) 789157
6/14µ(c) 31250
NAS CLASS 7
14/21µ(c) 250
NAS CLASS 3
21/38µ(c) 50
NAS CLASS 3
38/70µ(c) 14
NASCLASS 4
>70µ(c)  0
NAS CLASS 0